Download Schematic Drawings (PDF)

 

Select a schematic drawing:
Construction Joint - Walls & Slabs
Construction Joint - Walls/Slab Interface
Concrete Wall and Slab - Below Grade
Foundation Wall - Inside Application
Retaining Wall
Concrete Block Wall - Below Grade
Concrete Block Wall - Above Grade
Parking Deck
Roof/Plaza Deck
Elevator Pit/Sump Pit
Planter
Tunnel
Swimming Pool
Sewage Plant Clarifier Tank
Sewage Plant Digester Tank
Reservoir/Wet Well
Underground Vault/Dry Well
Precast Concrete Manhole
Standard Metal Pipe Detail
Ferro-Cement Boat, Caisson, Floating Dock
Bridge

 
Print Friendly Version
Download as PNG
Download as PDF

1. Apply one slurry coat of Xypex Concentrate to structural slab at the rate of 1.5 lb./sq. yd. (0.8 kg/m2).

3. Apply a cove strip of Xypex Modified mortar over slab/wall construction joint so that the cove extends one inch (25 mm) up the wall and one inch (25 mm) out on to the deck surface.

2. Apply one slurry coat of Xypex Concentrate to joint surface between parapet wall and bridge deck at the rate of 2.0 lb./sq. yd. (1.0 kg/m2). Xypex must be applied no more than 24 hours prior to concrete placement.

4. Apply one slurry coat of Xypex Concentrate to wall surfaces at the rate of 1.5 lb./sq. yd. (0.8 kg/m2).

Note 1: Schematic diagram shows Xypex application details only and does not depict standard requirements for waterstops or expansion joint sealants.

Note 2: Schematic drawing shows Xypex Coating application. Specifier may consider the alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where applicable. Refer to Standard Specifications for more information.