Download Schematic Drawings (PDF)

 

Select a schematic drawing:
Construction Joint - Walls & Slabs
Construction Joint - Walls/Slab Interface
Concrete Wall and Slab - Below Grade
Foundation Wall - Inside Application
Retaining Wall
Concrete Block Wall - Below Grade
Concrete Block Wall - Above Grade
Parking Deck
Roof/Plaza Deck
Elevator Pit/Sump Pit
Planter
Tunnel
Swimming Pool
Sewage Plant Clarifier Tank
Sewage Plant Digester Tank
Reservoir/Wet Well
Underground Vault/Dry Well
Precast Concrete Manhole
Standard Metal Pipe Detail
Ferro-Cement Boat, Caisson, Floating Dock
Bridge

 
Print Friendly Version
Download as PNG
Download as PDF

1. Apply one slurry coat of Xypex Concentrate to hull exterior, gunwhales, and all exterior decks at the rate of 1.5 lb./sq. yd. (0.8 kg/m2).

2. Apply one coat of Xypex Modified to interior surface of hull at the rate of 1.5 lb./sq. yd. (0.8 kg/m2).

In the case of sealed, hollow-core caissons, step 2 is eliminated and the Concentrate slurry coat in step 1 should extend over entire exterior of unit.

Note 1: Schematic diagram shows Xypex application details only and does not depict standard requirements for waterstops or expansion joint sealants.

Note 2: Schematic drawing shows Xypex Coating application. Specifier may consider the alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where applicable. Refer to Standard Specifications for more information.