Download Schematic Drawings (PDF)

 

Select a schematic drawing:
Construction Joint - Walls & Slabs
Construction Joint - Walls/Slab Interface
Concrete Wall and Slab - Below Grade
Foundation Wall - Inside Application
Retaining Wall
Concrete Block Wall - Below Grade
Concrete Block Wall - Above Grade
Parking Deck
Roof/Plaza Deck
Elevator Pit/Sump Pit
Planter
Tunnel
Swimming Pool
Sewage Plant Clarifier Tank
Sewage Plant Digester Tank
Reservoir/Wet Well
Underground Vault/Dry Well
Precast Concrete Manhole
Standard Metal Pipe Detail
Ferro-Cement Boat, Caisson, Floating Dock
Bridge

 
Print Friendly Version
Download as PNG
Download as PDF

1. Prior to placement of the concrete wall and slab, apply one Xypex Concentrate to joint surfaces at the rate of 2.0 lb./sq. yd.

2. In sealing strip, apply one slurry coat of Xypex Concentrate 1.5 lb./sq. yd. (0.8 kg/m2), then fill slot to surface with Xypex in Dry-Pac form.

3. To exterior wall surface and footing, apply two slurry coats Concentrate at a rate of 1.25 to 1.5 lb./sq. yd. (0.65 to 0.8 kg). The second coat should be applied after the first coat still “green”.

4. Apply a cove strip of Xypex Modified mortar to exterior of footing and block wall.

Because of the variances in the quality of concrete block (e.g. cement content, porosity, etc.), please consult your Xypex technical representative.

Note 1: Schematic diagram shows Xypex application details only and does not depict standard requirements for waterstops or expansion joint sealants.

Note 2: Schematic drawing shows Xypex Coating application. Specifier may consider the alternative use of Xypex Dry Shake (DS-Series), Xypex Additive (Admix C-Series) or Xypex Megamix I, where applicable. Refer to Standard Specifications for more information.